TYCO ESFR Sprinkler Supplier

TYCO ESFR sprinkler for high-piled storage – Reactra

TYCO ESFR Sprinkler Supplier

Reactra is a trusted TYCO ESFR sprinkler supplier, offering genuine UL/FM-approved ESFR models for high-bay warehouses and high-piled storage. We provide expert selection support—matching K-factor, temperature rating, and hydraulic design to your commodity and ceiling height—plus full documentation and fast PAN-India delivery to ensure your warehouse protection is code-compliant and ready for installation.

14.0 K-factor Pendent Sprinklers

The TYCO Model ESFR-14, K-factor Pendent Sprinklers are Early Suppression, Fast Response sprinklers with a nominal K-factor of 14.0. They are suppression-mode sprinklers that are especially advantageous as a means of eliminating the use of in-rack sprinklers when protecting high-piled storage. This Model Sprinklers are primarily designed for protection of the following
storage arrangements:

• Most encapsulated or non-encapsulated common materials including cartooned, unexpanded plastics
• Some storage arrangements of rubber tires, roll paper, flammable liquids For more specific criteria, see Table B and the applicable design standard.

More About Products Details Given In The Data Sheet:

K-factor Pendent Sprinklers

16.8 K-factor Pendent Sprinklers (For Europe Only)

The TYCO Model ESFR-17 Pendent Sprinklers are Early Suppression, Fast Response sprinklers with a nominal K-factor of 16.8.  They are suppression mode sprinklers that are especially advantageous as a means of eliminating in-rack sprinklers when protecting high-piled storage. This Model Pendent Sprinklers are primarily used for ceiling-only sprinkler protection.

This Model Pendent Sprinklers provide the system designer with hydraulic and sprinkler placement options not presently available to traditional ESFR Sprinklers having a nominal K-factor of 14.0. In particular, Model ESFR-17 Pendent Sprinklers are designed to operate at substantially lower-end head pressures, as compared to ESFR Sprinklers having a nominal K-factor of 14.0. This feature offers flexibility when sizing system piping, as well as possibly reducing or eliminating the need for a system fire pump.

More About Products Details Given In The Data Sheet:

16.8 K-factor Pendent Sprinklers (For Europe Only)

16.8 K-factor Upright Sprinkler

The TYCO Model ESFR-17 Upright Sprinklers are Early Suppression, Fast Response sprinklers with a nominal K-factor of 16.8. The sprinkler assembly is shown in Figure 1. They are suppression mode sprinklers that are especially advantageous as a means of eliminating in-rack sprinklers when protecting high-piled storage.

The Model ESFR-17 Upright Sprinklers provide the system designer with an upright option to the traditional pendent ESFR Sprinklers. With a K-factor of 16.8, Model ESFR-17 Sprinklers provide system designers with hydraulic and sprinkler placement options not presently available to traditional ESFR Sprinklers having a K-factor of 14.0. In particular, the Model ESFR-17 Upright Sprinklers are designed to operate at substantially lower-end head pressures compared to ESFR Sprinklers with 14.0 K-factor. This feature offers flexibility when sizing system piping and positioning the system piping with respect to the ceiling.

More About Products Details Given In The Data Sheet:

16.8 K-factor Upright Sprinkler

22.4 K-factor Pendent Sprinklers

The TYCO Model ESFR-22 Pendent Sprinklers are Early Suppression, Fast Response  sprinklers with a nominal K-factor of 22.4. The sprinklers’ suppression-mode design is especially advantageous as a means of eliminating the use of in-rack sprinklers when protecting high-piled storage. The Model ESFR-22 Sprinklers are primarily used for ceiling-only sprinkler protection of the following storage applications:
• Most encapsulated or non-encapsulated common materials including cartooned, unexpanded plastics
• Uncartooned (exposed) expanded plastics in accordance with NFPA 13 and FM Global standards
• Some storage arrangements of rubber tires, roll paper, flammable liquids, and aerosols.

More About Products Details Given In The Data Sheet:

22.4 K-factor Pendent Sprinklers

25.2 K-factor Pendent Sprinkler

The TYCO Model ESFR-25 Pendent Sprinklers are Early Suppression, Fast Response sprinklers with a nominal K-factor of 25.2. They are suppression-mode sprinklers that are especially advantageous as a means of eliminating the use of in-rack sprinklers when protecting high-piled storage. The Model ESFR-25 Pendent Sprinklers provide the system designer with hydraulic and sprinkler placement options not presently available to the traditional ESFR sprinklers having nominal K-factors of 14.0 and 16.8. In particular, the Model ESFR-25 Sprinkler is designed to operate at substantially lower-end head pressures, as compared to ESFR Sprinklers having nominal K-factors of 14.0 and 16.8. This feature offers flexibility when sizing system piping, as well as possibly reducing or eliminating the need for a system fire pump.

More About Products Details Given In The Data Sheet:

25.2 K-factor Pendent Sprinkler

25.2 K-factor Upright Sprinkler

The TYCO Model EC-25, Extended Coverage 25.2K Upright Sprinkler is a UL Listed, standard response, extended coverage Control Mode Density Area (CMDA) sprinkler for storage applications. It is also FM Approved as a quick response, extended coverage CMDA sprinkler and as a Control Mode Specific Application (CMSA) sprinkler, as well as FM Approved for storage and non-storage applications. When used in accordance with National Fire Protection Association
(NFPA) 13, smoke vents and draft curtains are not required as specified in the 2015 edition of the International Building Code (IBC) and International Fire Code (IFC) for CMSA sprinklers with an RTI of 50 or less and a design of 12 or fewer sprinklers.

More About Products Details Given In The Data Sheet:

25.2 K-factor Upright Sprinkler
33.6 K-factor Pendent Sprinklers

TYCO Model ESFR-34 Pendent Sprinklers are Early Suppression, Fast Response Sprinklers having a nominal K-factor of 33.6  They are suppression-mode sprinklers that are especially advantageous as a means of eliminating the use of in-rack sprinklers when protecting high-piled storage. The Model ESFR-34 can protect a storage arrangement of 50 ft. (15,2 m) with a ceiling height of 55 ft. (16,8 m) without requiring in-rack sprinklers. In addition, it can be installed with a maximum centerline of thermal sensing element-to-ceiling distance of 17 in. (432 mm). 

More About Products Details Given In The Data Sheet:

33.6 K-factor Pendent Sprinklers

When it comes to fire protection, Reactra Engineering Private Limited is your trusted partner. We go beyond being mere distributors and stockists; we provide comprehensive solutions tailored to meet your specific requirements. Our team of experts possesses in-depth knowledge of Tyco products and can assist you in selecting the ideal TYCO Series ESFR Sprinklers to safeguard your premises effectively.

Contact us today to discuss your fire protection needs, request a quote, or inquire about our range of Tyco products. We look forward to serving you and helping you create a safer environment for your business.

Why Choose Reactra Engineering

Authorized Distributor

Reactra Engineering is an Authorized Distributor of Tyco products,
ensuring that you have access to genuine and reliable solutions directly from the manufacturer. Our partnership with Tyco guarantees the highest quality standards and the latest technological advancements in the industry.

Extensive Product Range

We offer a comprehensive portfolio of products, catering to various industries and applications. From industrial automation to fire protection, security systems to energy management, our diverse range of solutions allows you to find everything you need under one roof, simplifying your procurement process.

Quality and Reliability

We understand the importance of quality and reliability when it comes to your business operations. Tyco is renowned for its stringent quality control processes and adherence to international standards. By choosing us, you can be confident in the performance and durability of the Tyco products you receive.

Technical Expertise

Our team of experienced professionals possesses in-depth knowledge and expertise in Tyco products and their applications. We are well-equipped to provide technical assistance, product recommendations, and customized solutions to meet your specific requirements. Count on us to deliver comprehensive support throughout your journey with Tyco products.

Choose Reactra Engineering as your trusted partner and Authorized Distributor of Tyco products. Experience the difference of working with a company that prioritizes quality, reliability, and customer satisfaction. Contact us today to discuss your requirements and discover how we can help you achieve your business goals.

GET IN TOUCH

One Step Solution For All Your Fire Production Product Needs. We are dedicated to doing what we do best, With over decades of industry experience, we have the techno commercial solution for every need of our customer.

FOR GENERAL ENQUIRY

With over decades of experience, We have the techno commercial solution for every need of our customers.

Our Branches