With over decades of experience, We have the techno commercial solution for every need of our customers.
We are proud to be the authorized distributor and stockist of the renowned Tyco brand, specializing in providing high-quality fire protection solutions. With our extensive expertise and commitment to safety, we offer a comprehensive range of Tyco Series EC-5, 8, 11, and 14 Sprinklers.
we understand the importance of reliable fire suppression systems to protect lives and property. That’s why we have partnered with Tyco, a trusted name in the industry, known for its innovative and reliable fire protection products.
Our Products are designed to provide effective fire suppression in various applications, including residential, commercial, industrial, and institutional environments. These sprinklers are engineered to meet the highest standards of performance, durability, and efficiency, ensuring rapid response and efficient water distribution in the event of a fire.
The Series EC-5 Extended Coverage Pendent Sprinklers are decorative glass bulb sprinklers designed for use in light hazard occupancies. They are intended for use in automatic sprinkler systems designed in accordance with standard installation rules (e.g., NFPA 13) for a maximum coverage area of 400 ft2 (37,2 m2), as compared to the maximum coverage area of 225 ft2 (20,6 m2) for standard coverage sprinklers used in light hazard occupancies. The recessed version of the EC-5, intended for use in areas with a finished ceiling, uses the two-piece Style 50 Recessed Escutcheon. The Style 50 Recessed Escutcheon provides up to 3/8 inch (9,5 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut.
More About Products Details Given In The Data Sheet:
The Series EC-5, Extended Coverage Horizontal Sidewall Sprinklers are extended coverage, decorative 3 mm glass bulb type spray sprinklers designed for use in hydraulically calculated sprinkler systems in light hazard, commercial occupancies such as churches, restaurant seating areas, hotels, educational facilities, offices, etc. With their coverage up to 16 ft (4,9 m) wide by 24 ft (7,3 m) long and maximum deflector to ceiling distance of 18 in. (450 mm), they are designed for installation along a wall or the side of a beam and just beneath a smooth and level ceiling. Horizontal sidewall sprinklers are commonly used instead of pendent or upright sprinklers due to aesthetics or building construction considerations, where piping across the ceiling is not desirable.
The fast response thermal sensitivity rating of the Series EC-5, 3 mm Bulb Type Sprinklers provides a quick response extended coverage (QREC) rating for many of the coverage areas detailed in Tables B and C.
More About Products Details Given In The Data Sheet:
The TYCO Series RFII, 5.6 K-factor, Royal Flush Concealed Pendent Sprinklers, (TY3532), Quick Response, Extended Coverage, Light Hazard (ECLH) are decorative, 3 mm bulb type sprinklers featuring a flat cover plate designed to conceal the sprinkler. These sprinklers are optimal for architecturally sensitive areas such as hotel lobbies, office buildings, churches, and restaurants. The Series RFII sprinklers are intended for use in automatic sprinkler systems designed in accordance with standard installation rules (e.g., NFPA 13). The fast-response thermal sensitivity rating of the Series RFII (TY3532) provides for a quick response, extended coverage (QREC) rating up to a 20 ft. x 20 ft. coverage area.
More About Products Details Given In The Data Sheet:
The Series EC-8 Extended Coverage Pendent Sprinklers are decorative glass bulb sprinklers designed for use in light hazard occupancies. They are intended for use in automatic sprinkler systems designed in accordance with standard installation rules (e.g., NFPA 13) for a maximum coverage area of 400 ft2 (37,2 m2), as compared to the maximum coverage area of 225 ft2 (20,6 m2) for standard coverage sprinklers used in light hazard occupancies. The recessed version of the EC-8, intended for use in areas with a finished ceiling, uses either the two-piece Style 30 or 40 Recessed Escutcheon. The Style 30 Recessed Escutcheon provides up to 1/2 in. (12,7 mm) of total adjustment from the flush pendent position, whereas, the Style 40 provides 3/4 in. (19,1 mm) of vertical adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheons reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut.
More About Products Details Given In The Data Sheet:
TYCO Series TY-FRB 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick and Standard Response (Light Hazard) are decorative 3 mm glass bulb type spray sprinklers designed for use in hydraulically calculated sprinkler systems in light hazard, commercial occupancies such as churches, restaurant seating areas, hotels, educational facilities, offices, etc. With their coverage up to 16 ft. (4,9 m) wide by 24 ft. (7,3 m) long, they are designed for installation along a wall or the side of a beam and just beneath a smooth ceiling. Horizontal sidewall (HSW) sprinklers are commonly used instead of pendent or upright sprinklers due to aesthetics or building construction considerations, where piping across the ceiling is not desirable. The fast response thermal sensitivity rating of the Series TY-FRB, 3 mm bulb type sprinklers provides for a quick response extended coverage (QREC) rating for many of the coverage areas detailed in Tables B and C.
More About Products Details Given In The Data Sheet:
TYCO Series EC-11 and EC-14 Extended Coverage Upright and Pendent Sprinklers are decorative
glass-bulb sprinklers designed for use in light or ordinary hazard occupancies. They are intended for use in automatic sprinkler systems designed in accordance with standard installation rules, such as NFPA 13, for a maximum coverage area of 400 ft2 (37,2 m2) as compared to the maximum coverage area of 130 ft2 (12,1 m2) for standard coverage sprinklers used in ordinary hazard occupancies, Series EC-11 and EC-14 Extended Coverage Sprinklers feature a UL and C-UL Listing that permits their use with unobstructed or non-combustible obstructed ceiling construction as defined and permitted by NFPA 13, as well as a specific application listing for use under concrete tees.
Series EC-11 and EC-14 Extended Coverage Sprinklers have been fire tested to compare their performance to that of standard coverage spray sprinklers. These tests have shown that the protection provided is equal to or more effective than standard coverage spray sprinklers.
More About Products Details Given In The Data Sheet:
Contact us today to discuss your fire protection requirements and discover how our Tyco Series EC-5, 8, 11, and 14 Sprinklers can safeguard your property and the lives of those within it. Trust Reactra Engineering Private Limited for top-quality fire protection solutions you can rely on.